Fortron FSP180-50MP Flex ATX |
Peripheral
> Power Supply > Fortron > FSP180-50MP
|
|
FSP180-50MP
|
|
|
- MEDICAL-GRADE POWER SUPPLY UNIT is designed to meet or exceed the strictest operating requirement for medical systems
- High Efficiency
- Active PFC, Full Range
- 40mm industrial-duty ball bearing cooling fan with chrome fan guard
- LOW RIPPLE & NOISE
- OUTPUT OVER VOLTAGE PROTECTION
- SHORT CIRCUIT PROTECTION ON ALL OUTPUTS
- RESETTABLE POWER SHUT DOWN
- LOW NOISE DESIGN AT FULL LOAD
- 100% BURN-IN UNDER HIGH AMBIENT TEMPERATURE (50°C)
- VACUUM-IMPREGNATED TRANSFORMER
- MTBF: 100K HOURS AT 25°C
- 100% HI-POT TESTED
- LINE INPUT FUSE PROTECTION
- Dimensions : 190mm D x 81.5mm W x 40.5mm H
|
|
|
|
|
|
|
1 x 24 (easy to 20) PIN
|
1 x 4 PIN P4
|
1 x Floppy
|
3 x Molex
|
1 x SATA
|
|
|
|
Input Specifications:
Full Range Input
Frequency: 47-63Hz
50Amps-peak/115Vac
80Amps-peak/230Vac
4.0Amps/115Vac
2.0Amps/230Vac
Output Specifications:
Overload Protection: +5V:
32Amps; +3.3V:
32Amps, +12V: 20Amps
Short Circuit Protection: The short circuit on any DC output shall not cause any damage to the power supply, including the primary fuse
GENERAL SPECIFICATIONS:
17ms at 115Vac/60Hz
68% min. 115Vac at full load
68% min. 230Vac at full load
Power Good Signal: 100ms to 500 ms
ENVIRONMENTAL SPECIFICATIONS:
Operating temperature: 0°C to +50°C
Storage temperature: -20°C to +80°C
Humidity: 85% to 95% RH non-condensing
|
|
|
OUTPUT VOLTAGE
|
OUTPUT CURRENT
|
REGULATION
|
OUTPUT
|
MIN.(A)
|
MAX.(A)
|
LOAD
|
LINE
|
RIPPLE & NOISE
MAX.[P-P]
|
+5V
|
0.5
|
12.0
|
± 5%
|
± 1%
|
50mV
|
+12V
|
1.5
|
12.0
|
± 5%
|
± 1%
|
120mV
|
-12V
|
0.0
|
0.8
|
± 10%
|
± 1%
|
120mV
|
+3.3V
|
0.3
|
16.8
|
± 5%
|
± 1%
|
50mV
|
+5VSB
|
0.0
|
2.0
|
± 5%
|
± 1%
|
50mV
|
Remarks:
* TOTAL CURRENT OF +5V AND + 3.3V NOT EXCEED 61W
* TOTAL +5V AND 3.3V AND 12V POWER NOT EXCEED 161W |
|
|
|
|
|
|