Zippy P2G-5600G 2U Single |
Peripheral
> Power Supply > Zippy > P2G-5600G
|
|
|
- Output Wattage : 600W
- Best Solution for:
Server, Workstation, Storage System, IPC
- Dimension:
240.00 x 100.00 x 70.00 (mm)
9.45 x 3.94 x 2.76 (inch)
|
|
|
AC INPUT SPECIFICATION |
|
VOLTAGE: 90 ~ 264VAC FULL RANGE
FREQUENCY : 47 ~ 63 HZ
INPUT CURRENT: 9A(RMS) FOR 115VAC, 4.5A(RMS) FOR 230 VAC
INRUSH CURRENT: 50A MAX. FOR 115 VAC, 100A MAX. FOR 230 VAC
POWER FACTOR CORRECTION: PFC CAN REACH THE TARGET OF 95% AT 115/230VAC, FULL LOAD
|
|
DC INPUT SPECIFICATION |
OUTPUT VOLTAGE
|
OUTPUT CURRENT
|
REGULATION
|
OUTPUT
|
MIN.(A)
|
MAX.(A)
|
LOAD
|
LINE
|
RIPPLE & NOISE
MAX.[P-P]
|
+5V
|
0.5
|
25
|
±5%
|
± 1%
|
60mV
|
+12V
|
2
|
48
|
±5%
|
± 1%
|
120mV
|
-12V
|
0
|
0.5
|
±5%
|
± 1%
|
120mV
|
+3.3V
|
0.5
|
25
|
±5%
|
±1%
|
60mV
|
+5VSB
|
0.05
|
3
|
±5%
|
± 1%
|
60mV
|
Remarks:
* +5V AND +3.3V TOTAL OUTPUT MAX: 160W
* +5V, +3.3V AND +12V TOTAL MAX: 581.5W
* TOTAL POWER: 600W |
|
- TEMPERATURE RANGE: OPERATING 0℃ --- 50℃, STORAGE –20℃ --- 80℃
- HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE
- EFFICIENCY: 87~90% TYPICAL AT 115V, FULL LOAD
- LEAKAGE CURRENT: 3.5mA MAX. AT NOMINAL VOLTAGE
VAC
- POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
- OVER POWER PROTECTION: 110~160%
- OVER VOLTAGE PROTECTION: +3.3V→3.6~4.3V,
+5V→5.6~6.5V, +12V→13.2~15V
- OVER CURRENT PROTECTOIN: +3.3V→27.5~40A,
+5V→27.5~40A, +12V→52.8~72.8A
- SHORT CIRCUIT PROTECTION
- EMI: FCC CLASS B, CISPR22 CLASS B
- SAFETY: TO MEET UL, CUL, TV, CCC
- 3.3V / 5V / 12V REMOTE SENSING
- COOLING: ONE 60mm DC FAN
- DIMENSION: 240 (D) x 100 (W) x 70 (H) mm
- MEET IEC-1000-3-2 CLASS D
- *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
|
|
|
|
|